Description
API 16D Electric Control Systems

Our electric control systems are designed to comply with SY/T5053.2 and API Spec 16D standards and feature a fast plug-in facility, simplified automated controls with misoperation protection and a 120 minute backup battery. We can also supply to meet the ATEX explosion proof standard upon your request.
Features
- Uses advanced PLC and Profibus control technology to simplify and automate operation.
- Designed and manufactured to comply with SY/T5053.2 and API Spec 16D standards
- ATEX explosion-proof standard to meet European Security Standard CE available upon your request.
- 120 minute backup battery for normal operation in the event of sudden power loss.
- Stable working performance even under extreme working conditions.
- Driller’s panel displays operation status notice and features misoperation protection.
- Fast plug-in facility for easier installation.
Configuration Parameters of Electric Hydraulic Control System
| Model | Number of controlled objects | Accumulator unit | Explosionproof motor Power (Kw) | ||
|---|---|---|---|---|---|
| Total volume (L) | Available liquid volume (L) | Installation mode | |||
| FKDQ1600-14 | 14 | 80×20 | 800 | Side/rear | 18.5×2 |
| FKDQ1600-12 | 12 | 80×20 | 800 | Side/rear | 18.5×2 |
| FKDQ1600-10 | 10 | 80×20 | 800 | Side/rear | 18.5×2 |
| FKDQ1440-14 | 14 | 60×24 | 720 | Side/rear | 18.5×2 |
| FKDQ1280-10 | 10 | 80×16 | 640 | Side/rear | 18.5×2 |
| FKDQ1280-9 | 9 | 80×16 | 640 | Side/rear | 18.5×2 |
| FKDQ1280-8 | 8 | 80×16 | 640 | Side/rear | 18.5×2 |
| FKDQ1280-7 | 7 | 80×16 | 640 | Side/rear | 18.5×2 |
| FKDQ1200-9 | 9 | 60×20 | 600 | Side/rear | 18.5×2 |
| FKDQ1200-8 | 8 | 60×20 | 600 | Side/rear | 18.5×2 |
| FKDQ960-8 | 8 | 60×16 | 480 | Side/rear | 18.5×2 |
| FKDQ960-7 | 7 | 60×16 | 480 | Side/rear | 18.5×2 |
| FKDQ800-8 | 8 | 40×20 | 400 | Side/rear | 18.5 |
| FKDQ 800-7 | 7 | 40×20 | 400 | Side/rear | 18.5 |
| FKDQ 800-6 | 6 | 40×20 | 400 | Side/rear | 18.5 |
| FKDQ720-7 | 7 | 60×12 | 360 | Side/rear | 18.5 |
| FKDQ 720-6 | 6 | 60×12 | 360 | Side/rear | 18.5 |
| FKDQ 640-6 | 6 | 40×16 | 320 | Side/rear | 18.5 |
| FKDQ 640-5 | 5 | 40×16 | 320 | Side/rear | 18.5 |
| FKDQ 480-5 | 5 | 40×12 | 240 | Side/rear | 18.5 |
| FKDQ 480-4 | 4 | 40×12 | 240 | Side/rear | 18.5 |
| FKDQ320-5 | 5 | 40×8 | 160 | Side/rear | 15 |
| FKDQ320-4 | 4 | 40×8 | 160 | Side/rear | 15 |
| FKDQ320-3 | 3 | 40×8 | 160 | Side/rear | 15 |
| FKDQ240-3 | 3 | 40×6 | 120 | Side/rear | 15 |
| FKDQ200-4 | 4 | 25×8 | 100 | Side/rear | 15 |
| FKDQ160-3 | 3 | 40×4 | 80 | Side/rear | 15 |
| FKDQ150-2 | 2 | 50×3 | 75 | Side/rear | 15 |
| FKDQ125-3 | 3 | 25×5 | 62.5 | Side/rear | 7.5/11 |
| FKDQ80-3 | 3 | 40×2 | 40 | Side/rear | 7.5 |
| FKDQ80-2 | 2 | 40×2 | 40 | Side/rear | 7.5 |
| FKDQ75-2 | 2 | 25×3 | 62.5 | Side/rear | 7.5 |
| FKDQ63-2 | 2 | 63×1 | 31.5 | Side/rear | 7.5 |
| FKDQ50-2 | 2 | 25×2 | 25 | Side/rear | 7.5 |
| FKDQ40-2 | 2 | 40×1 | 20 | Side/rear | 7.5 |
| FKDQ25-2 | 2 | 25×2 | 12.5 | Side/rear | 7.5 |
| FKDQ25-1 | 1 | 25×2 | 12.5 | Side/rear | 7.5 |
| Model | Pump system displacement | Rated operating pressure of the system (Mpa) | Maximum operating pressure of the system (Mpa) | |
|---|---|---|---|---|
| Triplex pump (mL/r) | Pneumatic pump (mL/ stroke) | |||
| FKDQ1600-14 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1600-12 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1600-10 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1440-14 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1280-10 | 80×2 | 120×3 | 21 | 31.5 |
| FKDQ1280-9 | 80×2 | 120×3 | 21 | 31.5 |
| FKDQ1280-8 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ1280-7 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ1200-9 | 80×2 | 120×3 | 21 | 31.5 |
| FKDQ1200-8 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ960-8 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ960-7 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ800-8 | 80 | 120 | 21 | 31.5 |
| FKDQ 800-7 | 80 | 120 | 21 | 31.5 |
| FKDQ 800-6 | 80 | 120 | 21 | 31.5 |
| FKDQ720-7 | 80 | 120 | 21 | 31.5 |
| FKDQ 720-6 | 80 | 120 | 21 | 31.5 |
| FKDQ 640-6 | 80 | 120 | 21 | 31.5 |
| FKDQ 640-5 | 80 | 120 | 21 | 31.5 |
| FKDQ 480-5 | 80 | 120 | 21 | 31.5 |
| FKDQ 480-4 | 80 | 120 | 21 | 31.5 |
| FKDQ320-5 | 60 | 120 | 21 | 31.5 |
| FKDQ320-4 | 60 | 120 | 21 | 31.5 |
| FKDQ320-3 | 60 | 120 | 21 | 31.5 |
| FKDQ240-3 | 60 | 120 | 21 | 31.5 |
| FKDQ200-4 | 60 | 120 | 21 | 31.5 |
| FKDQ160-3 | 60 | 120 | 21 | 31.5 |
| FKDQ150-2 | 60 | 120 | 21 | 31.5 |
| FKDQ125-3 | 28 | – | 21 | 21 |
| FKDQ80-3 | 28 | – | 21 | 21 |
| FKDQ80-2 | 28 | – | 21 | 21 |
| FKDQ75-2 | 28 | – | 21 | 21 |
| FKDQ63-2 | 28 | – | 21 | 21 |
| FKDQ50-2 | 28 | – | 21 | 21 |
| FKDQ40-2 | 28 | – | 21 | 21 |
| FKDQ25-2 | 28 | – | 21 | 21 |
| FKDQ25-1 | 28 | – | 21 | 21 |
Main Technical Parameters of Electric Hydraulic Control System
| Normal pressure of the system: | 21 Mpa | 3000 psi |
|---|---|---|
| Pressure regulating range of the system: | 0~14 Mpa | 3000 psi |
| Nitrogen charging pressure of accumulator: | 7±0.7 Mpa | 3000 psi |
| Pressure switch setting range: | 18.9~21 Mpa | 2700~3000psi |
| Hydraulic/pneumatic switch setting range: | 18.9~21 Mpa | 2700~3000psi |
| Air supply pressure: | 0.65~0.8 Mpa | 93~115psi |
| Power supply: | 380±19V / 50Hz Optional as required by customers |
|
| Control power supply: | 24V DC | |
| Battery capacity: | 10Ah | |
| Communication interface: | Profibus-Dp |
Functional Configuration of Electric Hydraulic Control System
| Model | Electric oil pump | Pneumatic oil pump | Manual oil pump | Alarm device | Standby nitrogen system | Protection house |
|---|---|---|---|---|---|---|
| FKDQ1600-14 | • | • | ◊ | • | ◊ | • |
| FKDQ1600-12 | • | • | ◊ | • | ◊ | • |
| FKDQ1600-10 | • | • | ◊ | • | ◊ | • |
| FKDQ1440-14 | • | • | ◊ | • | ◊ | • |
| FKDQ1280-10 | • | • | ◊ | • | ◊ | • |
| FKDQ1280-9 | • | • | ◊ | • | ◊ | • |
| FKDQ 1280-8 | • | • | ◊ | • | ◊ | • |
| FKDQ1280-7 | • | • | ◊ | • | ◊ | • |
| FKDQ1200-9 | • | • | ◊ | • | ◊ | • |
| FKDQ1200-8 | • | • | ◊ | • | ◊ | • |
| FKDQ960-8 | • | • | ◊ | • | ◊ | • |
| FKDQ960-7 | • | • | ◊ | • | ◊ | • |
| FKDQ800-8 | • | • | ◊ | • | ◊ | • |
| FKDQ 800-7 | • | • | ◊ | • | ◊ | • |
| FKDQ 800-6 | • | • | ◊ | • | ◊ | • |
| FKDQ720-7 | • | • | ◊ | • | ◊ | • |
| FKDQ 720-6 | • | • | ◊ | • | ◊ | • |
| FKDQ 640-6 | • | • | ◊ | • | ◊ | • |
| FKDQ 640-5 | • | • | ◊ | • | ◊ | • |
| FKDQ 480-5 | • | • | ◊ | • | ◊ | • |
| FKDQ 480-4 | • | • | ◊ | • | ◊ | • |
| FKDQ320-5 | • | • | ◊ | • | ◊ | • |
| FKDQ320-4 | • | • | ◊ | • | ◊ | • |
| FKDQ320-3 | • | • | ◊ | • | ◊ | • |
| FKDQ240-3 | • | • | ◊ | • | ◊ | • |
| FKDQ200-4 | • | • | ◊ | • | ◊ | • |
| FKDQ160-3 | • | • | ◊ | • | ◊ | • |
| FKDQ150-2 | • | • | ◊ | • | ◊ | • |
| FKDQ125-3 | • | x | ◊ | • | ◊ | • |
| FKDQ80-3 | • | x | ◊ | • | ◊ | • |
| FKDQ80-2 | • | x | ◊ | • | ◊ | • |
| FKDQ75-2 | • | x | ◊ | • | ◊ | • |
| FKDQ63-2 | • | x | ◊ | • | ◊ | • |
| FKDQ50-2 | • | x | ◊ | • | ◊ | • |
| FKDQ40-2 | • | x | ◊ | • | ◊ | • |
| FKDQ25-2 | • | x | ◊ | • | ◊ | • |
| FKDQ25-1 | • | x | ◊ | • | ◊ | • |
| Model | Insulated House | Driller’s console | Auxiliary console | Pipe rack and hose | PN-T automatic recording system | Zero pressure starting system |
|---|---|---|---|---|---|---|
| FKDQ1600-14 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1600-12 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1600-10 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1440-14 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1280-10 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1280-9 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 1280-8 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1280-7 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1200-9 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ1200-8 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ960-8 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ960-7 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ800-8 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 800-7 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 800-6 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ720-7 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 720-6 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 640-6 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 640-5 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 480-5 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ 480-4 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ320-5 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ320-4 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ320-3 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ240-3 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ200-4 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ160-3 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ150-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ125-3 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ80-3 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ80-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ75-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ63-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ50-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ40-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ25-2 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
| FKDQ25-1 | ◊ | • | ◊ | ◊ | ◊ | ◊ |
Note:
- Listed above are basic configurations of our products, where, “•” represents basic configuration and “◊” optional.
- The optional configuration here doesn’t mean that it is available in any model, which should be discussed at time of contract conclusion.
- Protection room width: 2100mm for common room and 2300mm for room with thermal insulation.
- Listed above are basic configurations, but special design and manufacturing can be provided upon request.
- The auxiliary driller’s console can be based on buttons or touch screen
- Pneumatic pump is not available to FKDQ series liquid control equipment. The remote console must be provided with air supply interface for pneumatic control.




Our company has been in the oil & gas drilling equipment industry for over more years, We are here to serve all your drilling equipment needs.
Reviews
There are no reviews yet.