Drilling Parameter Instrument monitor

Description

Drilling Parameters Monitor with concentrated electric gauges

Introduction:

Drilling Parameter instrument combines technologies of electron, computer and communication, and it fits electric/mechanical/workover/offshore rigs. It monitors parameters of hook load, rotary torque, standpipe pressure, tong line pulling, SPM1&2&3; rotary RM and mud return flow.

•Components and features:

It is consisted of screen with gauges, data acquisition box (DAQ), sensors, background workstation, power supply unit and system program.

The monitor adopts screen with gauges to show data. The screen can be embedded in a bigger console or work as an independent one. It is small and compact, and fits well. The DAQ can be installed in electric-controlled room or in dog’s house according to real conditions on site. Power supply unit concludes industrial switch power-source and on-line UPS.

The background industrial PC workstation is used to record and deal the data in remote area and showing data in digits, curves and analog charts. It also restore, review and print data in curve and reports and preset alarm limits. The Chinese screen can switch to English.

The system is EX designed with anti-electromagnet, water-proof and anti-seismic. The technology of industrial bus makes the system run stable in complex conditions.

• Specifications:

1.Measure scale and error

Parameters Measure Range Display error Record error Remarks
Hook load   0 ~ 4200kN ±1.5% ±1.5% Or user choose
Standpipe pressure   0 ~ 40MPa ±2.5% ±1.5%
Rotary torque   0 ~ 1000A ±2.5% ±1.5% No measure Scale
Tong torque   0 ~ 100kN ±2.5% ±1.5%
Pump SPM 1/2/3   0 ~ 200SPM ±1.5% ±1.5%
Rotary RPM   0 ~ 300RPM ±1.5% ±1.5%
Mud return flow   0 ~ 100% ±1.5% ±1.5%
Mud tank volume   0.25 ~ 5m ±1.5% ±1.5%
H2S   0 ~ 100ppm ±2.5 % ±1.5% Density alarm

2.System guideline

Analog input for DAQ:8 ~ 16 channel

Digital input for DAQ:2 ~ 4 channel

Switch output for DAQ:4 channel

Sampling accuracy:1 sec.

Bit error rate:o bigger than 10-8 from DAQ to background workstation

Transmitting distance to workstation:200m

3.Working conditions:

Ambient temperature:parts in open -25℃~70℃(standard type),-40℃~70℃(low-temp. type)

Parts in door 0℃~40℃

Humidity:≤85%RH

Power supply:220VAC±20% ,50Hz±10% or 110VAC±20% ,60Hz±10%

power with no interruption > 2 hours (On-line UPS)

Drilling Parameter Instrument monitor with two-gauge screen

 

It is special for workover rig and rigs of less than 2000m, or when display console is too small for many gauges.

Drilling Parameter Instrument monitor with three-gauge screen

It is special for workover rig and rigs of less than 2000m, or when display console is too small for many gauges

Drilling Parameter Instrument monitor with four-gauge screen

 

 

 

 

Reviews

There are no reviews yet.

Be the first to review “Drilling Parameter Instrument monitor”

Your email address will not be published.